Abstract:
The project entitled “ARCHITECTURAL AND STRUCTURAL DESIGN FOUR STORIES BUILDING
HOTEL” was aimed to provide the adequate structural design of the hotel. This should solve the problem
of lacking of modern hotel. In order to accomplish this work some methodologies were adopted where,
the ARCHICAD software was used to architectural drawing, PROKON and analytical method was used
to design Structure elements like slab, beam, column, ground beam, foundation, and stairs.
Cross sections and reinforcements of all structure elements were calculated. Maximum cross section in
slab was 3.02 cm2/m with steel reinforcement of 68 /m at the top and bottom, the maximum area of beam
was 12.57 cm2 with steel reinforcement of 4Φ20 at the top and bottom was 4Φ14 of steel reinforcement
with corresponding area As = 6.16 cm2. The maximum area of ground beam was 6.61 cm2 with the steel
reinforcement of 4Φ14 at the top and 6.61 cm2 with steel reinforcement of 4Φ14 at the bottom. Maximum
area on ground floor part of column was 39.27 cm2 with steel reinforcement of 418, on first floor part of
column was 30.41 cm2with steel reinforcement of 412, on second floor part of column was 25.13cm2
with steel reinforcement of 412, on third floor part of column was 20.36 cm2 with steel reinforcement of
412, on fourth floor part of column was 16.08 cm2 with steel reinforcement 612, for stairs the maximum
area was As =10.18cm2/m with steel reinforcement .
ARCHITECTURAL AND STRUCTURAL DESIGN OF FOUR STORIE